Not for AEUC
Precondition
| Energize A/C | |
| ELAC 1 | ON |
| SEC 1 | ON |
| ELAC 2 | ON |
| SEC 2 | ON |
| SEC 3 | ON |
| ADIRU 1 - 3 | NAV |
| PTU | AUTO |
| ECAM | ON |
| ECAM | CLR all Faults |
| YELLOW | OFF |
| GREEN | OFF |
| BLUE | ON |
Open CBs
| PANEL | LOC | DESIGNATION |
| 49VU | D02 | ANTI ICE/PROBES/PITOT/1 |
| 49VU | D04 | ANTI ICE/PROBES/AOA/1 |
| 122VU | Y11 | ANTI ICE/PROBES/2/STATIC |
| 122VU | Y13 | ANTI ICE/PROBES/2/AOA |
| 122VU | Y14 | ANTI ICE/PROBES/2/PITOT |
| 122VU | Y15 | ANTI ICE/PROBES/2/TAT |
| 122VU | Z12 | ANTI ICE/PROBES/1/TAT |
| 122VU | Z13 | ANTI ICE/PROBES/1/STATIC |
| 122VU | Z14 | ANTI ICE/PROBES/3/STATIC |
| 122VU | Z15 | ANTI ICE/PROBES/3/AOA |
| 122VU | Z16 | ANTI ICE/PROBES/3/PITOT |
| 122VU | W13 | ANTI ICE/WHC/2 |
| 122VU | W14 | ANTI ICE/WINDOWS/R |
| 122VU | X13 | ANTI ICE/WHC/1 |
| 122VU | X14 | ANTI ICE/WINDOWS/L |
| 123VU | AF03 | ANTI ICE/R/WSHLD |
| 123VU | AF10 | ANTI ICE/L/WSHLD |
A: Operational Test of the Logics That Activate Elevator Aileron Computers 1 and 2 (ELAC 1 and 2) and Spoiler Elevator Computer 1 (SEC 1) Standby Power-Supplies
|
ACTION
|
RESULT
|
|
1.Open circuit breakers
49VU-B11 49VU-B08 |
On the overhead panel, on FLT CTL panel 23VU:
-
The FAULT legends of the ELAC 1 and SEC 1
pushbutton switches are off.
|
|
2.On the overhead panel, on maintenance panel 50VU, release the
BLUE PUMP OVRD pushbutton switch.
|
On the overhead panel, on maintenance panel 50VU:
-
The ON legend of the BLUE PUMP OVRD
pushbutton switch goes off.
|
|
On the overhead panel, on FLT CTL panel 23VU:
-
The FAULT legends of the ELAC 1 and SEC 1
pushbutton switches are off.
|
|
|
After approximately 30 seconds:
-
On the overhead panel, on FLT CTL panel
23VU, the FAULT legends of the ELAC 1 and
SEC 1 pushbutton switches come on.
-
On the upper ECAM Display Unit (DU), the
ELAC 1 FAULT and SEC 1 FAULT warnings come
into view.
-
On the lower ECAM DU, the ELAC 1 and SEC 1
legends change to amber.
|
|
|
3.On the overhead panel, on maintenance panel 50VU, push the
BLUE PUMP OVRD pushbutton switch.
|
On the overhead panel, on maintenance panel 50VU:
-
The ON legend of the BLUE PUMP OVRD
pushbutton switch comes on.
|
|
The ELAC 1 FAULT and SEC 1 FAULT warnings stay in view.
|
|
|
4.Close circuit breakers
49VU-B11 49VU-B08 |
On the overhead panel, on FLT CTL panel 23VU:
-
The FAULT legends of the ELAC 1 and SEC 1
pushbutton switches go off.
|
|
On the upper ECAM DU:
-
The ELAC 1 FAULT and SEC 1 FAULT warnings
go out of view.
|
|
|
On the lower ECAM DU:
-
The ELAC 1 and SEC 1 legends change to
green.
|
|
|
5.Open circuit breakers
121VU- R32 121VU- Q34 49VU- C09 121VU- R20 -
Ignore the warnings related to the other
systems.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch comes on.
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning comes into view.
|
|
|
On the lower ECAM DU:
-
The ELAC 2 legend changes to amber.
|
|
|
6.Open circuit breaker
121VU-Q16 |
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch goes off.
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning goes out of view.
|
|
|
On the lower ECAM DU:
-
The ELAC 2 legend changes to green.
|
|
|
After approximately 30 seconds:
-
On the lower ECAM DU, the ELAC 2 legend
changes to amber again.
-
On the upper ECAM DU, the ELAC 2 FAULT
warning comes into view.
-
On the overhead panel, on FLT CTL panel
24VU, the FAULT legend of the ELAC 2
pushbutton switch is off.
|
|
|
7.On the overhead panel, on the HYD section of panel 40VU, push
the YELLOW/ELEC PUMP pushbutton switch.
|
On the overhead panel, on the HYD section of panel 40VU:
-
The ON legend of the YELLOW/ELEC PUMP
pushbutton switch comes on.
|
|
8.On the overhead panel, on maintenance panel 50VU, release the
BLUE PUMP OVRD pushbutton switch.
|
On the overhead panel, on maintenance panel 50VU:
-
The ON legend of the BLUE PUMP OVRD
pushbutton switch goes off.
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch is off.
|
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning goes out of view.
|
|
|
On the lower ECAM DU:
-
The ELAC 2 legend changes to green.
|
|
|
9.On the overhead panel, on maintenance panel 50VU, push the
BLUE PUMP OVRD pushbutton switch.
|
On the overhead panel, on maintenance panel 50VU:
-
The ON legend of the BLUE PUMP OVRD
pushbutton switch comes on.
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning comes into view.
|
|
|
On the lower ECAM DU:
-
The ELAC 2 legend changes to amber.
|
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch is off.
|
|
|
10.On the overhead panel, on the HYD section of panel 40VU,
release the YELLOW/ELEC PUMP pushbutton switch.
|
On the overhead panel, on the HYD section of panel 40VU:
-
The ON legend of the YELLOW/ELEC PUMP
pushbutton switch goes off.
|
|
11.Close circuit breakers
121VU-R32 49VU-C09 121VU-Q34 |
On the lower ECAM DU:
-
The ELAC 2 legend changes to green.
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning goes out of view.
|
|
|
12.Open circuit breakers
121VU-R32 49VU- C09 121VU- Q34 |
On the lower ECAM DU:
-
The ELAC 2 legend is green.
|
|
On the upper ECAM DU:
-
There is no ELAC 2 FAULT warning.
|
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch is off.
|
|
|
13.Close circuit breakers
121VU-R32 49VU- C09 121VU- Q34 |
On the lower ECAM DU:
-
The ELAC 2 legend is green.
|
|
On the upper ECAM DU:
-
There is no ELAC 2 FAULT warning.
|
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch is off.
|
|
|
14.Go to paragraph B.
|
B: Operational Test of the Sidestick Priority Function
|
ACTION
|
RESULT
|
|
1.On the overhead panel, on FLT CTL panel 23VU, release the
ELAC 1 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the ELAC 1 pushbutton
switch comes on.
|
|
On the lower ECAM Display Unit (DU):
-
The ELAC 1 legend changes to amber.
-
The ELAC 2 legend stays green.
|
|
|
2.On the overhead panel, on FLT CTL panel 23VU, release the SEC
1 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the SEC 1 pushbutton
switch comes on.
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch comes on.
|
|
|
On the lower ECAM DU:
-
The SEC 1 legend changes to amber.
-
The ELAC 2 legend changes to amber.
|
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning comes into view.
|
|
|
3.On the overhead panel, on FLT CTL panel 23VU, push the ELAC 1
pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the ELAC 1 pushbutton
switch goes off.
|
|
On the overhead panel, on FLT CTL panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton
switch goes off.
|
|
|
On the lower ECAM DU:
-
The ELAC 1 legend changes to green.
-
The ELAC 2 legend changes to green.
|
|
|
On the upper ECAM DU:
-
The ELAC 2 FAULT warning goes out of view.
|
|
|
4.On the overhead panel, on FLT CTL panel 23VU, push the SEC 1
pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the SEC 1 pushbutton
switch goes off.
|
|
On the lower ECAM DU:
-
The SEC 1 legend changes to green.
|
|
|
5.On the CAPT and F/O sides:
-
Move the two side sticks around their axes
at the same time.
|
You can hear an aural announcement: DUAL INPUT.
|
|
On glareshield panels 130VU and 131VU, on the SIDE STICK
PRIORITY/CAPT and the SIDE STICK PRIORITY F/O annunciators:
-
The green CAPT and F/O legends flash at the
same time.
|
|
|
6.At the same time, on the CAPT side, push and hold the
takeover-and-priority pushbutton switch for less than 30
seconds.
|
You can hear an aural warning: PRIORITY LEFT.
On the F/O side, on glareshield panel 130VU:
-
The red arrow of the SIDE STICK
PRIORITY/F/O annunciator comes on.
|
|
-
On the F/O side, move the side stick to the
left, then to the neutral position.
|
On the CAPT side, on glareshield panel 131VU:
-
The green CAPT legend comes on, then goes
off.
|
|
7.On the CAPT side:
-
Release the takeover-and-priority
pushbutton switch.
|
On the F/O side, on glareshield panel 130VU:
-
The red arrow of the SIDE STICK
PRIORITY/F/O annunciator goes off.
|
|
8.At the same time, on the F/O side, push and hold the
takeover-and-priority pushbutton switch for less than 30
seconds.
|
You can hear an aural warning: PRIORITY RIGHT.
On the CAPT side, on glareshield panel 131VU:
-
The red arrow of the SIDE STICK
PRIORITY/CAPT annunciator comes on.
|
|
-
On the CAPT side, move the side stick to
the left, then to the neutral position.
|
On the F/O side, on glareshield panel 130VU:
-
The green F/O legend comes on, then goes
off.
|
|
9.On the F/O side:
-
Release the takeover-and-priority
pushbutton switch.
|
On the CAPT side, on glareshield panel 131VU:
-
The red arrow of the SIDE STICK
PRIORITY/CAPT annunciator goes off.
|
|
10.Go to paragraph C.
|
C: Check of the Ailerons movement
|
ACTION
|
RESULT
|
|
1.On the CAPT side:
-
Move the side stick to the left until it touches the
stop.
|
On the lower ECAM display unit:
-
The L/AIL index moves to the upper stop
-
The R/AIL index moves to the lower stop
-
The left spoiler 3 extends.
|
|
2.On the CAPT side:
-
Move quickly the side stick from the left to the right
in less than 2 seconds.
|
On the lower ECAM display unit:
-
The L/AIL index moves to the lower stop (the total
travel time is approximately 5 seconds)
-
The R/AIL index moves to the upper stop (the total
travel time is approximately 5 seconds)
-
The left spoiler 3 retracts
-
The right spoiler 3 extends.
|
|
3.On the CAPT side:
-
Move the side stick to the neutral position.
|
On the lower ECAM display unit:
-
The R/AIL and L/AIL indexes go back to the neutral
position
-
The right spoiler 3 retracts.
|
|
4.Close the circuit breakers
121VU-R20 121VU-Q16 |
On the overhead panel 24VU:
-
The FAULT legend of the ELAC 2 pushbutton switch is
off.
|
|
On the lower ECAM display unit:
-
The ELAC 2 legend is green.
|
|
|
5.Go to Para D.
|
D: Operational Test of the Ability of Elevator Aileron Computer 1 (ELAC 1) and Spoiler Elevator Computers 1 and 2 (SECs 1 and 2) to Get the Pitch Control
|
ACTION
|
RESULT
|
|
1.Pressurize the Green and Yellow hydraulic systems
|
On the lower ECAM Display Unit (DU):
-
The G and Y indications become green.
|
|
2.Depressurize the Blue hydraulic system
|
On the lower ECAM DU, on the F/CTL page:
-
The B indication becomes amber.
|
|
3.Wait for five seconds.
|
|
|
4.Pressurize the Blue hydraulic system
|
On the lower ECAM DU, on the F/CTL page:
-
The B indication becomes green.
|
|
5.On the overhead panel, on FLT CTL panel 23VU:
-
Release the SEC 1 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the SEC 1 pushbutton switch comes on.
|
|
6.On the overhead panel, on FLT CTL panel 24VU:
-
Release the ELAC 2 and SEC 2 pushbutton switches.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legends of the ELAC 2 and SEC 2 pushbutton
switches come on.
|
|
7.On the CAPT or F/O side:
-
Pull the side stick rearward until it touches the stop
position, and move the side stick back to the neutral
position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the L/ELEV and R/ELEV indicators move up
and go back to the neutral positions.
|
|
8.On the overhead panel, on FLT CTL panel 23VU:
-
Push the SEC 1 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the SEC 1 pushbutton switch goes off.
|
|
9.On the overhead panel, on FLT CTL panel 24VU:
-
Push the ELAC 2 and SEC 2 pushbutton switches.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legends of the ELAC 2 and SEC 2 pushbutton
switches go off.
|
|
10.Depressurize the Green and Yellow hydraulic systems.
|
On the lower ECAM DU, on the F/CTL page:
-
The G and Y indications become amber.
|
|
11.Wait for five seconds.
|
|
|
12.Pressurize the Green and Yellow hydraulic systems
|
On the lower ECAM DU, on the F/CTL page:
-
The G and Y indications become green.
|
|
13.On the overhead panel, on FLT CTL panel 23VU:
-
Release the ELAC 1 and SEC 1 pushbutton switches.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legends of the ELAC 1 and SEC 1 pushbutton
switches come on.
|
|
14.On the overhead panel, on FLT CTL panel 24VU:
-
Release the ELAC 2 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legend of the ELAC 2 pushbutton switch comes
on.
|
|
15.On the CAPT side:
-
Give the instructions that follow one after the other,
and keep the side stick in each position for three
seconds:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2 and 5 move
in relation to the side stick instructions.
|
|
16.On the F/O side:
-
Give the instructions that follow one after the other,
and keep the side stick in each position for three
seconds:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2 and 5 move
in relation to the side stick instructions.
|
|
17.Set the pitch-trim control wheel to the 10 UP position.
|
|
|
18.On the overhead panel, on FLT CTL panel 24VU:
-
Release the SEC 2 pushbutton switch and then push it
again.
|
On the center pedestal:
-
After approximately five seconds, the pitch-trim
control wheel goes back automatically to the "0"
position.
On the lower ECAM DU, on the F/CTL page:
-
The PITCH TRIM indicator shows 0 DEG plus or minus 0.3.
|
|
19.Set the pitch-trim control wheel to the 3 DN position.
|
|
|
20.On the overhead panel, on FLT CTL panel 24VU:
-
Release the SEC 2 pushbutton switch and then push it
again.
|
On the center pedestal:
-
After approximately five seconds, the pitch-trim
control wheel goes back automatically to the "0"
position.
On the lower ECAM DU, on the F/CTL page:
-
The PITCH TRIM indicator shows 0 DEG plus or minus 0.3.
|
|
21.On the overhead panel, on FLT CTL panel 23VU:
-
Push the ELAC 1 and SEC 1 pushbutton switches.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legends of the ELAC 1 and SEC1 pushbutton
switches go off.
|
|
22.On the overhead panel, on FLT CTL panel 24VU:
-
Push the ELAC 2 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legend of the ELAC 2 pushbutton switch goes
off.
|
|
23.Depressurize the Blue hydraulic system
|
On the lower ECAM DU, on the F/CTL page:
-
The B indication becomes amber.
|
|
24.Wait for five seconds.
|
|
|
25.Pressurize the Blue hydraulic system
|
On the lower ECAM DU, on the F/CTL page:
-
The B indication becomes green.
|
|
26.On the overhead panel, on FLT CTL panel 23VU:
-
Release the ELAC 1 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 23VU:
-
The OFF legend of the ELAC 1 pushbutton switch comes
on.
|
|
27.On the overhead panel, on FLT CTL panel 24VU:
-
Release the ELAC 2 and SEC 2 pushbutton switches.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legends of the ELAC 2 and SEC 2 pushbutton
switches come on.
|
|
28.On the CAPT side:
-
Give the instructions that follow one after the other,
and keep the side stick in each position for three
seconds:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2, 3 and 4
move in relation to the side stick instructions.
|
|
29.On the F/O side:
-
Give the instructions that follow one after the other,
and keep the side stick in each position for three
seconds:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2, 3 and 4
move in relation to the side stick instructions.
|
|
30.Set the pitch-trim control wheel to the 10 UP position.
|
|
|
31.On the overhead panel, on F/CTL panel 23VU:
-
Release the SEC 1 pushbutton switch and then push it
again.
|
On the center pedestal:
-
After approximately five seconds, the pitch-trim
control wheel goes back automatically to the "0"
position.
On the lower ECAM DU, on the F/CTL page:
-
The PITCH TRIM indicator shows 0 DEG plus or minus 0.3.
|
|
32.Set the pitch-trim control wheel to the 3 DN position.
|
|
|
33.On the overhead panel, on F/CTL panel 23VU:
-
Release the SEC 1 pushbutton switch and then push it
again.
|
On the center pedestal:
-
After approximately five seconds, the pitch-trim
control wheel goes back automatically to the "0"
position.
On the lower ECAM DU, on the F/CTL page:
-
The PITCH TRIM indicator shows 0 DEG plus or minus 0.3.
|
|
34.Open circuit breakers
49VU-B11 121VU- R20 |
On the upper ECAM DU:
-
The F/CTL ELAC 1 FAULT and F/CTL ELAC 2 FAULT messages
come into view.
|
|
35.On the CAPT or F/O side:
-
Give the instructions that follow one after the other:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2, 3 and 4
move in relation to the side stick instructions.
|
|
36.On the overhead panel, on FLT CTL panel 24VU:
-
Push the SEC 2 pushbutton switch.
|
On the overhead panel, on FLT CTL panel 24VU:
-
The OFF legend of the SEC 2 pushbutton switch goes off.
|
|
37.On the overhead panel, on F/CTL panel 23VU:
-
Release the SEC 1 pushbutton switch.
|
On the overhead panel, on F/CTL panel 23VU:
-
The OFF legend of the SEC 1 pushbutton switch comes on.
|
|
38.On the CAPT or F/O side:
-
Give the instructions that follow one after the other:
- Full nose up
- Full nose down
- Full right turn
- Full left turn.
-
Move the side stick back to the neutral position.
|
On the lower ECAM DU, on the F/CTL page:
-
The indexes of the elevators and spoilers 2 and 5 move
in relation to the side stick instructions.
|
|
39.Close circuit breakers
49VU-B11 121VU- R20 |
On the upper ECAM DU:
-
The F/CTL ELAC 1 FAULT and F/CTL ELAC 2 FAULT messages
go out of view.
|
Close CBs
| PANEL | LOC | DESIGNATION |
| 122VU | W13 | ANTI ICE/WHC/2 |
| 122VU | W14 | ANTI ICE/WINDOWS/R |
| 122VU | X13 | ANTI ICE/WHC/1 |
| 122VU | X14 | ANTI ICE/WINDOWS/L |
| 123VU | AF03 | ANTI ICE/R/WSHLD |
| 123VU | AF10 | ANTI ICE/L/WSHLD |
| 49VU | D02 | ANTI ICE/PROBES/PITOT/1 |
| 49VU | D04 | ANTI ICE/PROBES/AOA/1 |
| 122VU | Y11 | ANTI ICE/PROBES/2/STATIC |
| 122VU | Y13 | ANTI ICE/PROBES/2/AOA |
| 122VU | Y14 | ANTI ICE/PROBES/2/PITOT |
| 122VU | Y15 | ANTI ICE/PROBES/2/TAT |
| 122VU | Z12 | ANTI ICE/PROBES/1/TAT |
| 122VU | Z13 | ANTI ICE/PROBES/1/STATIC |
| 122VU | Z14 | ANTI ICE/PROBES/3/STATIC |
| 122VU | Z15 | ANTI ICE/PROBES/3/AOA |
| 122VU | Z16 | ANTI ICE/PROBES/3/PITOT |
Close out
| BLUE | OFF |
| YELLOW | OFF |
| GREEN | OFF |
| ELAC 1 | ON |
| SEC 1 | ON |
| ELAC 2 | ON |
| ADIRU 1 - 3 | OFF |
| ECAM | OFF |